Forced Draft Air Cooled Heat Exchangers with Chimney On Top
Transheat scope
Thermal design with performance guarantee, Mechanical design, structure design and specification of bought out items.
Chimney arrangement on top of tube bundle to take care of partial heat load during fan failure / power off condition
Installation location : India .
All design documents reviewed by : Thyssen.
Major design attributes
- Two Forced draft air cooled heat exchangers provided with a chimney arrangement on top of the tube bundles.
- This ensures that partial heat duty is met during fan failure / power off conditions – to meet client requirements.
- Design code – ASME Sec. VIII Div. 1
- All drawings and material lists generated from 3D model.