VDU Fired Heater
Transheat scope
The overall scope for the complete project was to perform Mechanical design,Structure Design, refractory design, piping stress analysis, specifications for bought out items, complete 3D modelling of heaters with interconnecting flue gas ducts, fabrication drawings and material lists from the same 3D model.
Transheat has inhouse performed the complete structure design for complete heater with self supporting stack mounted on top of convection section.
Installation location : Middle East.
Major design attributes
Box type fired heater with radiant section, convection section (with on board APH with ducting connected with burner as well as FD fan) and top mounted self supported stack. Stair tower till convection section.
Software used for Structure design :
STAAD Pro and in-house excel spread sheet.