Transheat

Transheat expertise lies in providing quality design services for process plants

Transheat expertise lies in providing quality design services for process plants

Finite Element Analysis of Cover type Air Cooled Heat Exchanger header box

Home / Project Portfolio / Air Cooled Heat Exchangers/Fin Fan Cooler / Finite Element Analysis of Cover type Air Cooled Heat Exchanger header box

Transheat scope

Performing Finite Element Analysis (FEA) for the inlet and outlet cover type header boxes with consideration of the design conditions and the specified nozzle loads. Ensure that stresses within the header boxes are within the code allowable limits while considering the various load cases and boundary conditions.
All design documents reviewed by :ASME AI.

Major design attributes

Rules of ASME Sec. VIII Div. 2 Part 5 are used with ASME Sec. VIII Div. 1 allowable stress values to determine acceptability of the design

Scroll to Top