Transheat scope

Performing Finite Element Analysis (FEA) for the inlet and outlet cover type header boxes with consideration of the design conditions and the specified nozzle loads. Ensure that stresses within the header boxes are within the code allowable limits while considering the various load cases and boundary conditions.
All design documents reviewed by :ASME AI.

Major design attributes

Rules of ASME Sec. VIII Div. 2 Part 5 are used with ASME Sec. VIII Div. 1 allowable stress values to determine acceptability of the design